Firestone New Product: Single-Ply LVOC Primer & Splice Wash

With an increased focus on environmentally friendly, Low Volatile Organic Compounds (LVOC) products, Firestone Building Products is pleased to introduce Single-Ply LVOC Primer, as well as, Single-Ply LVOC Splice Wash. These two new products provide an LVOC option for use in cleaning and preparing either RubberGard™ EPDM or UltraPly™ TPO membranes to receive QuickSeam™ tape products.

The new Single-Ply LVOC Primer has been extensively tested and proven to provide superior adhesion with QuickSeam products and complies with VOC limit requirements.

Single-Ply LVOC Primer Benefits:

  • Ensures excellent initial and long-term bond strength
  • Flashes off much quicker than the QuickPrime LVOC Primer
  • Meets the VOC air quality requirements of the South Coast Air Quality Management District (SCAQMD) and Ozone Transport Commission (OTC) and can be used anywhere in the U.S.

The new Single-Ply LVOC Splice Wash is designed to clean RubberGard EPDM and UltraPly TPO seams wherever a 250 g/L VOC limit is mandated. Single-Ply LVOC Splice Wash works to ensure a superior seam and to improve the performance of Firestone primers, adhesives and sealants. Single-PLY LVOC Splice Wash can be used in all OTC areas, but not in California air districts that use the SCAQMD regulations.

Due to new regulations, contractors are required to use Single-Ply LVOC Primer and Single-Ply LVOC Splice Wash for both UltraPly TPO and RubberGard EPDM roofing membrane systems in states regulated by the Ozone Transport Commission (OTC) model rule requiring limited emissions of volatile organic compounds (VOCs) – MAX 250 g/L. OTC member states include: Connecticut, Delaware, the District of Columbia, Maine, Maryland, Massachusetts, New Hampshire, New Jersey,
New York, Pennsylvania, Rhode Island, Vermont and Virginia, as of January 1, 2012.

These new products complement Firestone’s full line of low VOC products and demonstrate Firestone’s continued commitment to provide our customers with environmentally friendly products, while maintaining the high level of quality and performance expected from Firestone.

Please contact your Roof Systems Advisor, 1-800-428-4511 for the latest code approvals for this product. Additional information is available from your local Firestone Sales Representative or visit the Firestone Building Products website at www.firestonebpco.com. Thanks for your continued support.

Single-Ply LVOC Primer 3 gallon W563587110
Single-Ply LVOC Primer 1 gallon; 4/ctn     W563587111
Single-Ply LVOC Splice Wash     3 gallon W563587113



1 comment (Add your own)

1. KIRAFuts wrote:
To determine internal swelling is difficult enough, therefore, consequently, they influence the body for a long time, which threatens the normal fetus. Fluids are dangerous because they break blood circulation. Such situation leads to worsening feeding and the breath baby, created hypoxia.
Fighting such a pathology should be done with the help of correction feeding and special exercises so that fluid does not stay tissues. If expectant mother is resting, then under the feet preferably put a cushion or pillow to improve the blood circulation of tired legs. Prohibited long time to sit or stand, as this leads to stagnation in the body. It is recommended that the knee-elbow position several times a day in order to increase blood flow.
[url=http://pregnancyplus.info/what-causes-swollen-feet-after-giving-birth]swollen feet after giving birth[/url]

Mon, July 2, 2018 @ 5:55 PM

Add a New Comment


code
 

Comment Guidelines: No HTML is allowed. Off-topic or inappropriate comments will be edited or deleted. Thanks.

    Copyright 2018 Heartland Architectural Products. All Rights Reserved.

    4334 N. Meridian Ave.

    Oklahoma City, OK / 73112

    Phone (405) 601-6147 / Fax (405) 212-4931


The information presented on this website was assembled with care and is believed to be current and accurate on the date presented; however, the information was prepared by the manufacturers represented and not by Heartland Architectural Products LLC, Kevin W. Decker and David Gary, who cannot and does not extend any warranty either express or implied for the company or themselves or on behalf of the manufacturer, all of which are disclaimed, including without limitation, the implied warranty of fitness for a particular purpose. Services by Heartland Architectural Products LLC, Kevin W. Decker and David Gary are not intended or offered in substitution for the design professional’s judgment and due diligence. It is expected that a design professional will exercise professional judgment and due diligence before issuing Contract Documents for a specific application under a professional seal and signature in accordance with applicable laws.